Projects
March 2003
● Project
Number: 10-01-01055
In
2002 Fisher-Klosterman, Inc. secured an order for a sanitary fabric
collector to clean the exhaust gas of a pharmaceutical spray dryer.
Sanitary construction was required in order to prevent product
contamination as well as expedite the cleaning process. The unit
features a polished stainless steel interior, PTFE coated pleated
filter elements, and a davited roof assembly for access to the
filters. The collector is also designed to vent a dust explosion per
NFPA guidelines.
| |
Design Conditions: |
|
1200 ACFM @ 70 ˚F
Filter Velocity = 3.5 fpm |
Features: 316 stainless steel, #4 polished interior,
compressed air pulse system, PTFE coated pleated filters, davited
roof assembly, explosion venting, NEMA 9 control panel, sanitary
access door and nickel plated valves
WHY FKI FABRIC COLLECTORS?
- Custom engineered for your specific application requirements.
- Available materials of construction include mild steel,
stainless steel & alloys, aluminum, fiberglass, and plastic.
- Wide range of gas flows available (1 to >100,000 CFM).
- Available filter media: polyester, polypropylene, fiberglass,
cotton, acrylic, Nomex®, P84®, Teflon®, Ryton®, metal, ceramic,
standard bags, cartridges, and pleated filter elements are
available.
- Available options: high temperature or pressure design,
polished welds and surfaces, break-apart construction, explosion
venting, and ASME code construction.
|
 |
 |
|
 |



Contact Us
Fisher-Klosterman, Inc.
PO Box 11190 Louisville, KY 40251-0190 Phone (502) 572-4000 Fax (502) 572-4025
Buell Division
200 North 7th Street Suite 2 Lebanon, PA 17046 Phone (717) 274-7104 Fax (717) 274-7342
Fisher-Klosterman-Buell Shanghai Co., Ltd.
No. 80, 1030 Lane Heng' An Road Pudong New District Shanghai,2000137,P.R.C. Phone 011-86-21-50673100 Fax 011-86-21-50673074
|