Project # 10-01-01125
Due to recent changes in EPA regulations, brick and tile manufacturers must now comply with MACT requirements for HF, HCl, SO2, and dust emissions on their kiln exhausts. FKI was approached by a leading supplier in the industry to make recommendations and offer a proposal to clean the kiln exhausts at three of their plants. Though the technology had not been used on this process before, wet scrubber / absorber systems were designed, proposed, and finally installed in May 2003. Each system supplied included a quench section, a packed tower section, ductwork, an exhaust fan, pumps, piping and valves, instrumentation, a control panel with starters, a stack with platform and ladder, a make-up water tank package, a bleed tank package, and a caustic tank package. Materials of construction included FRP, CPVC, and alloy C276. In June 2003 the first of the stack emissions tests was completed. The results proved that wet scrubbing technology is the solution for the brick and tile industry. The removal efficiencies achieved are much higher than traditional dry scrubbers and are more economical.

DESIGN CONDITIONS:

                            

Plant A

Plant B

Plant C

Gas flow, acfm:   

23,650

17,800

58,483

DP, "H2O:

7

7

7

HF Conc., ppmv:     

112

202

118

HCl conc., ppmv:   

10

14

40

SO2 Conc., ppmv:     

14

24

60

Dust loading, lb/hr:     

2.0

2.4

6.1

 

FIELD RESULTS:

 

Efficiency %

HF

99.8

HCl

98.0

SO2

88.0

 

These efficiencies exceed the required permit levels

  High Efficiency Cyclone used in a Lumber Mill


Why FKI Scrubber/Absorber Systems?

  • Custom engineered for your specific application requirements
  • Combination of quench / dust removal / gas absorption in one compact unit.
  • Wide range of quench, venturi throat, .moisture separator, liquid introduction, and packing media designs
  • Complete system responsibility: Fan, pump, piping and valves, instruments, controls, duct, stack, access steel
  • Efficiencies to meet your permit requirements


Project of the Month
Recent Projects

Contact Us

Fisher-Klosterman, Inc.
PO Box 11190
Louisville, KY 40251-0190
Phone (502) 572-4000
Fax (502) 572-4025

Buell Division
200 North 7th Street Suite 2
Lebanon, PA 17046
Phone (717) 274-7104
Fax (717) 274-7342

Fisher-Klosterman-Buell Shanghai Co., Ltd.
No. 80, 1030 Lane
Heng' An Road
Pudong New District
Shanghai,2000137,P.R.C.
Phone 011-86-21-50673100
Fax 011-86-21-50673074